QYWN-01 hydraulic brake rubber cups for automobiles working durability test device
overview :
Hydraulic brake rubber cups for automobiles working durability test device,according to HG2865-1997 standard (Appendix B). Durability test device work by cabinet electric double layer heating constant temperature box, built-in type body structure, combine with hydraulic, electric,gas to test durability, control by computer and PLC to communication and routinization control,realize the real-time data acquisition, display, setting and control. Hydraulic control system is used to drive hydraulic solenoid valve to the main cylinder piston for reciprocating movement, the test specimen in a certain pressure, a certain frequency, a certain return trip, a certain temperature of the leather bowl, the amount of interference, determine whether the durability of the specimen is in line with the standard. The durability testing device of the work is in accordance with the “HG2865-1997” standard (Appendix B test method for the durability test of automotive hydraulic brake rubber.
Component:
1、The double layered electric heating thermostatic box
2、The built-in frame
3、The hydraulic station and hydraulic pipeline
4、The electrical control and detection (an instrument), display 5、The liquid storage tank
6、It can promote the device
7、One wheel cylinder device
Technical data:
Heating temperature |
Room temperature:-180℃ |
Control frequency accuracy |
±0.1%。 |
Control temperature accuracy |
±1℃ |
Counting range |
0-4X105 adjustable |
Pressure setting and detection range |
0-25MPa 0-100KPa |
Counting accuracy |
±1 |
Pressure control accuracy |
≥1MPa±0.5% ≤100 KPa±0.1%。 |
Cooling temperature range |
Room temperature:-45℃(variation frequency refrigeration control) |
Maximum timing |
0.0-9999h59min59s |
Control accuracy |
±0.5℃ |
Timing accuracy |
±0.1s |
Drive device movement range |
0.00~20.00mmadjustable |
Setting test frequency |
0.1000~0.5000HZ(can be setting) |
Displacement detection accuracy |
±0.01mm. |
Volume measurement range |
0.0ml~500 ml |
Loading power setting range |
0~150W |
Measurement accuracy |
±0.5 ml |
Loading power setting accuracy |
±0.1W |
Residual pressure test range |
0.0~1MPa |
Detection accuracy |
±0.3‰ |
Measurement accuracy |
±0.01 MPa |
Force detection range |
0.00~2500N |